CTI | Cti2000.it
Viale Elvezia, 12 - 20154 Milano
Tel. +39 02 266.265.1
Fax +39 02 266.265.50
P.IVA 11494010157
Path: Home » Indice Pubblicazioni » Convegni ATI - Accesso riservato soci CTI » CA - 62 - Fisciano 2007 » Experimental characterization of an a...
Autore: B, Belvedere, M. Bianchi, A. Borghetti, A. De Pascale
Collana: CA - 62 - Fisciano 2007
Note:
The paper presents a developed test facility, equipped with a Digital Signal Processor (DSP), for the experimental characterization of an autonomous Auxiliary Power Unit (APU), which is based on a Proton Exchange Membrane (PEM) fuel cell and a set of electrochemical batteries, both connected to a common AC bus through power electronic converters. The paper also describes a steady state model for the simulation of the APU; the model is specifically tuned for a 4.8 kW commercial PEM fuel cell by means of experimental data acquired by the test facility.