Path: Home » Attività Normativa » CT 243 - Impianti di raffrescamento: pompe di calore, condizionatori, scambiatori, compressori » CEN/TC 113 » Norme Pubblicate
In questa sezione è riportata tutta la documentazione del Gruppo Consultivo o della Commissione Tecnica, suddivisa tra attività nazionale svolta direttamente e attività CEN e/o ISO svolta dalla CT in qualittà di Mirror Committee.
Pubblicazione UNI |
||||||
---|---|---|---|---|---|---|
00113037 |
EN 12900:2005 |
Refrigerant compressors - Rating conditions, tolerances and presentation of manufacturer's performance data |
This document specifies the rating conditions, tolerances and the method of presenting manufacturer’s data for positive displacement refrigerant compressors. These include single stage compressors, single and two stage compressors using a means of liquid subcooling. This is required so that a comparison of different refrigerant compressors can be made. The data relate to the refrigerating capacity and power absorbed and include correction factors and part-load performance where applicable. |
Sì |
|
|
00113040 |
EN 15879-1:2011 |
Testing and rating of direct exchange ground coupled heat pumps with electrically driven compressors for space heating and/or cooling - Part 1: Direct exchange-to-water heat pumps |
This standard specifies the terms and definitions, test conditions, test procedures and requirements for the rating and performance of direct exchange-to-water ground coupled heat pumps with electrically driven compressors, used for space heating and/or cooling. Brine can be used instead of water. Direct exchange-to-air ground coupled heat pumps are covered by EN XXX Part 2. This European standard applies to factory-made units. In the case of units consisting of several parts, this standard applies only to those designed and supplied as a complete package. This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant. |
Sì 24/03/2011 |
|
|
00113025 |
EN 12102:2008 |
Air conditioners, liquid chilling packages, heat pumps and dehumidifiers with electrically driven compressors for space heating and cooling - Measurement of airbone noise - Determination of the sound power level |
This European Standard establishes requirements for determining, in accordance with a standardized procedure, the sound power level emitted into the surrounding air by air-conditioners, heat-pumps, liquid chilling packages with electrically driven compressors when used for space heating and/or cooling, including water cooled multisplit systems, as described in EN 14511 and dehumidifiers as described in EN 810. It is emphasized that this measurement standard only refers to airbone noise. |
Sì |
|
|
00113052 |
UNI EN 12900:2013 |
Refrigerant compressors - Rating conditions, tolerances and presentation of manufacturer's performance data |
This European Standard specifies the rating conditions, tolerances and the method of presenting manufacturer's data for positive displacement refrigerant compressors. These include single stage compressors and single and two stage compressors using a means of liquid subcooling. This is required so that a comparison of different refrig-erant compressors can be made. The data related to the refrigerating capacity and power absorbed, include correc-tion factors and part-load performance where applicable. |
Sì 19/09/2013 |
|
|
00113055 |
EN 16583:2015 (UNI EN 16583:2016) |
Heat exchangers - Hydronic room fan coils units - Determination of the sound power level |
This European Standard specifies the terms and definitions, test conditions, test procedures and requirements for the acoustic performance of fan-coil units, taking into account the non-ducted as well as the ducted units |
Sì 09/06/2016 |
|
|
00113058 |
UNI CEN ISO/TS 16491:2017 (CEN ISO/TS 16491:2 |
Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests (ISO/TS 16491:2012) |
- |
Sì 04/05/2017 |
|
|
00113061 |
EN 12102:2013 (UNI EN 12102:2014) |
Air conditioners, liquid chilling packages, heat pumps and dehumidifiers with electrically driven compressors for space heating and cooling - Measurement of airborne noise - Determination of the sound power level |
- |
Sì 05/06/2014 |
|
|
00113067 |
UNI EN 13771-2:2018 (EN 13771-2:2017) |
Compressors and condensing units for refrigeration - Performance testing and test methods - Part 2: Condensing units |
- |
Sì 01/02/2018 |
|
|
00113069 |
UNI EN 13771-1:2017 (EN 13771-1:2016) |
Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors |
- |
Sì 04/05/2017 |
|
|
00113080 |
UNI EN 12102-2:2019 |
Air conditioners, liquid chilling packages, heat pumps, process chillers and dehumidifiers with electrically driven compressors - Determination of the sound power level - Part 2: Heat pump water heaters |
- |
Sì 24/07/2019 |
|
|
00113069CN |
CN - EN 13771-1:2016 |
CORRECTION NOTICE - Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors |
- |
Prossima |
|
|
00113082 |
UNI EN 13215:2020 |
Condensing units for refrigeration - Rating conditions, tolerances and presentation of manufacturer's performance data |
- |
Sì 29/10/2020 |
|
|
00113083 |
UNI EN 1397:2022 (EN 1397:2021) |
Heat exchangers - Hydronic room fan coil units - Test procedures for establishing the performance |
- |
Sì 24/02/2022 |
|
|
00113086 |
UNI EN 14511-2:2022 |
Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 2: Test conditions |
- |
Sì 13/10/2022 |
|
|
00113087 |
UNI EN 14511-3:2022 |
Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 3: Test methods |
- |
Sì 13/10/2022 |
|
|
00113088 |
UNI EN 14511-1:2022 |
Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 1: Terms and definitions |
- |
Sì 13/10/2022 |
|
|
00113089 |
UNI EN 12102-1:2022 |
Air conditioners, liquid chilling packages, heat pumps, process chillers and dehumidifiers with electrically driven compressors - Determination of the sound power level - Part 1: Air conditioners, liquid chilling packages, heat pumps for space heating and cooling, dehumidifiers and process chillers |
- |
Sì 13/10/2022 |
|
|
00113090 |
UNI EN 14825:2022 |
Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling, commercial and process cooling - Testing and rating at part load conditions and calculation of seasonal performance |
- |
Sì 13/10/2022 |
|
|
00113092 |
UNI EN 14511-4:2022 |
Air conditioners, liquid chilling packages and heat pumps for space heating and cooling and process chillers, with electrically driven compressors - Part 4: Requirements |
- |
Sì 13/10/2022 |
|
|
00113093 |
UNI EN 16583:2022 |
Heat exchangers - Hydronic room fan coils units - Determination of the sound power level |
- |
Sì 13/10/2022 |
|
Codice progetto |
Codice Norma |
Titolo |
Sommario |
Pubblicazione UNI |
|
---|---|---|---|---|---|
00113024 |
CEN/TS 14825:2003 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Testing and rating at part load conditions |
This European Standard specifies the terms, definitions, rating conditions and requirements of variable capacity air conditioners and heat pumps with electrically driven compressors. |
Non prevista |
|
00113033 |
EN 13771-1:2003 |
Compressors and condensing units for refrigeration - Performance testing and test methods - Part 1: Refrigerant compressors |
This part 1 of the European Standard applies only to refrigerant compressors and describes a number of selected performance test methods. These methods provide sufficiently accurate results for the determination of the refrigerating capacity, power absorbed, refrigerant mass flow, isentropic efficiency and the coefficient of performance. This standard applies only to performance tests conducted at the manufacturer's works or wherever the equipment for testing to the accuracy required is available. The type of measuring instrument and the limits within which measurements shall be made are listed in normative annex A. |
Non prevista |
|
00113026 |
EN 14511-1:2004 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions |
This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled |
Non prevista |
|
00113027 |
EN 14511-2:2004 |
- Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions |
This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid |
Non prevista |
|
00113028 |
EN 14511-3:2004 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods |
This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air |
Non prevista |
|
00113029 |
EN 14511-4:2004 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Requirements |
This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid |
Non prevista |
|
00113038 |
EN 15218:2006 |
Air conditioners and liquid chilling packages with evaporatively cooled condenser and with electrically driven compressors for space cooling — Terms, definitions, test conditions, test methods and requirements |
This standard specifies the terms, definitions, test conditions, test methods and requirements for the rating and performance of air conditioners and liquid chilling packages, with electrically driven compressors and with evaporatively cooled condenser when used for space cooling. The evaporatively cooled condenser is cooled by air and by the evaporation of external additional water. This external additional water is fed by a specific water supply circuit or by a water tank. |
Non prevista |
|
00113C02 |
EN 14511-3:2004/AC:2004 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods |
This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling. It also specifies the method of testing and reporting for heat recovery capacities, system reduced capacities and the capacity of individual indoor units of multisplit systems, where applicable. This European Standard applies to factory-made units that can be ducted. This standard applies to factory-made liquid chilling packages with integral condensers or for use with remote condensers. This standard applies to factory-made units of either fixed capacity or variable capacity by any means. Packaged units, single split and multisplit systems are covered by this standard, except water-cooled multisplit systems. In the case of units consisting of several parts, the standard applies only to those designed and supplied as a complete package, except for liquid chilling packages with remote condenser. This standard is primarily intended for water and brine chilling packages but can be used for other liquid subject to agreement. This standard applies to air-to-air air conditioners which evaporate the condensate on the condenser side. The units having their condenser cooled by air and by the evaporation of external additional water are not covered by this standard. This standard does not apply to units using transcritical cycles, e.g. with CO2 as refrigerant. Installations used for heating and/or cooling of industrial processes are not within the scope of this standard. NOTE 1 Part load testing of units is dealt with in CEN/TS 14825. NOTE 2 All the symbols given in this text should be used regardless of the language used. |
Non prevista |
|
00113044 |
EN 14511-4:2007 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Requirements |
This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressor, are fit for the use designated by the manufacturer when used for space heating and/or cooling. |
Non prevista |
|
00113041 |
EN 14511-1:2007 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 1: Terms and definitions |
This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled |
Non prevista |
|
00113042 |
EN 14511-2:2007 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 2: Test conditions |
This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems. |
Non prevista |
|
00113043 |
EN 14511-3:2007 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods |
This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling. |
Non prevista |
|
00113034 |
EN 13771-2:2007 |
Compressors and condensing units for refrigeration - Performance testing and test methods - Part 2: Condensing units |
This part of EN 13771 applies only to condensing units for refrigeration and describes a number of selected performance test methods. These methods provide sufficiently accurate results for the determination of the refrigerating capacity, power absorbed, refrigerant mass flow, isentropic efficiency and the coefficient of performance. This European Standard applies only to performance tests conducted at the manufacturer's works or wherever the instrumention and load stability for testing to the accuracy required is available. The type of measuring instrument and the allowable uncertainty within which measurements shall be made are listed in normative Annex A. |
Non prevista |
|
00113045 |
UNI EN 14825:2012 |
Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling -Testing and rating at part load conditions and calculation of seasonal performance |
This European standard covers reduced capacity testing of air conditioners, heat pumps and liquid chilling packages for part load conditions |
Non prevista |
|
00113022 |
EN 13215:2000 |
Condensing units for refrigeration - Rating conditions, tolerances and presentation of manufacturer's performance data |
This European Standard specifies the rating conditions, tolerances and presentation of performance data for single-stage condensing units for refrigeration with compressors of the positive-displacement type. This is required so that a comparison of different condensing units can be made. The performance data relate to the refrigerating capacity and power absorbed, they include correction factors and refer to full load operation of the condensing unit. |
Non prevista |
|
00113046 |
UNI EN 14511-1:2011 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling — Part 1: Terms and definitions |
This part of EN 14511 specifies the terms and definitions for the rating and performance of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. |
Non prevista |
|
00113047 |
UNI EN 14511-2:2011 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling — Part 2: Test conditions |
This part of EN 14511 specifies the test conditions for the rating of air and water cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and/or cooling. It also specifies test conditions for heat recovery operation of multisplit systems. |
Non prevista |
|
00113048 |
UNI EN 14511-3:2011 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods |
This part of EN 14511 specifies the test methods for the rating and performance of air and water-cooled air conditioners, liquid chilling packages, air-to-air, water-to-air, air-to-water and water-to-water heat pumps with electrically driven compressors when used for space heating and cooling. |
Non prevista |
|
00113049 |
UNI EN 14511-4:2011 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 4: Requirements |
This part of EN 14511 specifies minimum requirements which ensure that air conditioners, heat pumps and liquid chilling packages with electrical driven compressor, are fit for the use designated by the manufacturer when used for space heating and/or cooling. |
Non prevista |
|
00113C03 |
EN 14511-3:2007/AC:2008 |
Air conditioners, liquid chilling packages and heat pumps with electrically driven compressors for space heating and cooling - Part 3: Test methods |
Text is not available |
Non prevista |
|