User

Password

Recupero Password

Path: Home » Attività  normativa » Energia dai rifiuti » CEN/TC 343 » Struttura » Solid recovered fuels - Method for th...

CEN/TC 343 - Energia dai rifiuti

Coordinatore GL: Dott. Ciceri Giovanni - Project Leader: Molinari Dario - Project Assistant: N.D. - Maggiori Informazioni

In questa sezione è riportata tutta la documentazione dell'attività del Gruppo di Lavoro, suddivisa tra attività nazionale svolta direttamente e attività CEN e/o ISO svolta dal GL in qualità di Mirror Committee.

Solid recovered fuels - Method for the determination of the content of major elements (Al, Ca, Fe, K, Mg, Na, P, Si, Ti)

Inchiesta

Scadenza: 18/06/2010

Data Documento: 28/01/2010
Organo Tecnico: CEN/TC 343 - Solid recovered fuels

Note:
This European Standard specifies three methods of digestion for solid recovered fuels: a) microwave assisted digestion with hydrofluoric, nitric and hydrochloric acid mixture; b) hot water bath digestion of with hydrofluoric, nitric and hydrochloric acid mixture, after ashing of the SRFs sample; c) oven digestion with nitric, perchloric and hydrofluoric acid mixture. Instrumental determination of Si, Al, K, Na, Ca, Mg, Fe, P, and Ti is performed by Inductively Coupled Plasma Spectrometry with optical detection or other suitable spectroscopic techniques such as Flame Atomic Spectroscopy. The effectiveness of the digestion can be verified by qualitative X-ray fluorescence (XRF) analysis on the remaining residue. If necessary an alternative digestion method (among those proposed) needs to be used. XRF can be used for the analysis of Si, Al, K, Na, Ca, Mg, Fe, P, Ti, after ashing (550 °C) of the sample: other elements can be analysed by XRF providing that the concentration levels are above the instrumental detection limits of the XRF instrumentation and after proper preliminary testing. Method a) is recommended for general use, but the amount of the test portion can be very low in case of high concentration of organic matter. Method b) is recommended for SRFs with high organic matter concentration that can be difficult to digest with the other methods. Method c) is recommended for SRFs samples for which the other methods leave a significant insoluble residue. All the listed methods are suitable for the determination of Si, provided that closed containers are used for sample dissolution. XRF is highly recommended for Si, P and Ti analysis.


Per scaricare il Documento devi essere loggato!



Viale Elvezia, 12 - 20154 Milano
Tel. +39 02 266.265.1
Fax +39 02 266.265.50
P.IVA 11494010157

Social CTI

Seguici!

Twitter LinkedIn

Disclaimer - Privacy