Pubblicazione UNI |
||||||
---|---|---|---|---|---|---|
00089058 |
EN 1946-5:2000 |
Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 5: Measurements by pipe test methods |
This part 5 of this standard provides specific technical criteria for the assessment of laboratories to undertake steady-state heat transfer property measurenets on circular pipe insulation according to EN ISO 8497:1994 |
Sì |
|
|
00089057 |
EN 1946-4:2000 |
Thermal performance of building products and components - Specific criteria for the assessment of laboratories measuring heat transfer properties - Part 4: Measurements by hot box methods |
This part 4 of this standard provides specific technical criteria for the assessment of laboratories to undertake steady-state heat transfer property measurements on products and components using calibrated or guarded hot box apparatus in accordance with EN ISO 8990:1996, including its application to doors and windows in accordance with EN ISO 12567, or using a heat flow meter in a hot box apparatus in accordance with EN 1934:1998 |
Sì |
|
|
00089078 |
EN 13363-2:2005 |
Solar protection devices combined with glazing - Calculation of solar and light transmittance - Part 2: Detailed calculation method |
This standard specifies a detailed method, based on the spectral transmission data of the materials comprising the solar protection devices and the glazing, to determine the total solar energy transmittance and other relevant solar-optical data of the combination. If spectral data are not available the methodology can be adapted to use integrated data.The method is valid for all types of solar protection devices parallel to the glazing such as louvre, venetian or roller blinds. The blind may be located internally, externally, or enclosed between the panes of the glazing. Ventilation of the blind is allowed for in each of these positions in determining the distribution of solar energy absorbed by the glazing or blind components.The blind component materials may be transparent, translucent or opaque, combined with glazing components with known solar transmittances and reflectances and with known emissivities for thermal radiation.The standard also gives certain normalised situations, additional assumptions and necessary boundary conditions. |
Sì |
|
|
00089073 |
EN ISO 12567-2:2005 |
Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 2: Roof windows and other projecting windows (ISO/DIS 12567-2:2000) |
This standard specifies a method to measure the thermal transmittance of roof windows and projecting windows.It does not include:- edge effects occuring outside the perimeter of the specimen;- energy transfer due to solar radiation on the specimen;- effects of air leakage through the specimen. |
Sì |
|
|
00089027 |
EN ISO 15927-1:2003 |
Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 1: Monthly means of single meteorological elements (ISO 15927-1:2003) |
This European Standard specifies procedures for calculating and presenting the monthly means of those parameters of climatic data needed to assess some aspects of the thermal and moisture performance of buildings. Numerical values for any locations should be obtained from the meteorological service in the relevant country.This European Standard covers the following single climate variables: air temperature; atmospheric humidity; wind speed; precipitation; solar radiation; longwave radiation.Meteorological instrumentation and methods of observation are not covered; these are specified by the World Meteorological Organisation (WMO). |
Sì |
|
|
00089074 |
EN 12412-4:2003 |
Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 4: Roller shutter boxes |
This European Standard specifies a method, based on EN ISO 8990 and EN ISO 12567-1, to measure the overall thermal transmittance of a roller shutter box in a hot box. This includes all effects of geometrical and material characteristics in a test specimen.Edge effects occurring outside of the perimeter of the specimen are excluded. Furthermore, energy transfer due to solar radiation is not taken into account, and air leakage is excluded.The method is designed to provide both standardised tests which enable a fair comparison of different products to be made, and specific tests on products for practical application purposes. The former includes window standardised specimen sizes and applied test criteria.The determination of the overall thermal transmittance is performed for conditions which will correspond to a similar situation of the roller shutter box in practice.Information on the design of the calibration transfer standard is given in EN ISO 12567-1. |
Sì |
|
|
00089075 |
EN 12412-2:2003 |
Thermal performance of windows, doors and shutters - Determination of thermal transmittance by hot box method - Part 2: Frames |
This European Standard specifies a method, based on EN ISO 8990 and EN ISO 12567-1, to measure the thermal transmittance of frame and sash components of windows and doors, including mullions and transoms.The thermal bridging effect of window or door components (handles, hinges, closing devices, etc.) is included.The test procedure is designed to take into account the whole developed area of the frame or sash surface, but excludes the influence of the thermal bridge introduced through the spacer in sealed glazing units.Edge effects occurring outside of the perimeter of the specimen are excluded. Furthermore, energy transfer due to solar radiation is not taken into account, and air leakage is excluded.The measurements are performed under defined conditions to facilitate the comparison of measured values.Information on the design of the calibration transfer standard is given in EN ISO 12567-1. |
Sì |
|
|
00089069 |
EN ISO 15927-4:2005 |
Hygrothermal performance of buildings - Climatic data - Part 4: Data for assessing the annual energy demand for cooling and heating systems (ISO/DIS 15927-4:2000) |
This part of ISO 15927 specifies a method for constructing a reference year of hourly values of appropriate meteorological data suitable for assessing the average annual energy for heating and cooling. |
Sì |
|
|
00089116 |
CEN/TR 15601:2012 |
Hygrothermal performance of buildings - Resistance to wind - driven rain of roof coverings with discontinuously laid small elements - Test methods |
This European Standard specifies a method of test for determining the resistance of pitched roof coverings to wind-driven and deluge rain. The test method is applicable to discontinuously laid unsealed small roof covering elements such as clay tiles, concrete tiles, slates, fibre cement slates and stones. |
Sì |
|
|
00089115 |
prEN ISO 15927-3 |
Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 3: Calculation of a driving rain index for vertical surfaces from hourly wind and rain data (ISO/FDIS 15927-3:2008) |
This standard specifies two procedures for providing an estimate of the quantity of water likely to impact on a wall of any given orientation. It takes account of topography, local sheltering and the type of building and wall. |
Sì |
|
|
00089114 |
EN ISO 15927-2:2009 |
Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 2: Hourly data for design cooling load (ISO 15927-2:2009) |
To draft a standard giving the definition and specifying methods of calculation and presentation of the monthly external design climate to be used in determining the design cooling load of buildings. |
Sì |
|
|
00089110 |
EN 15217:2007 |
Energy performance of buildings - Methods for expressing energy performance and for energy certification of buildings |
This standard defines: |
Sì |
|
|
00089113 |
EN ISO 9346:2007 |
Hygrothermal performance of buildings and building materials - Mass transfer - Physical quantities for mass transfer - Vocabulary (ISO 9346:2007) |
This European Stabdard describes the hygrothermal performance of buildings and building materials ;Physical quantities for mass transfer; Vocabulary (ISO 9346:2007) |
Sì |
|
|
00089045 |
EN 15255:2007 |
Energy performance of buildings - Sensible room cooling load calculation - General criteria and validation procedures |
This standard sets out the level of input and output data and prescribes the boundary conditions required for a calculation method of the sensible cooling load of a single room under constant and/or floating temperature, taking into account the limit of the peak cooling load of the system. It fixes the critera to be met by a calculation method and gives examples of calculation methods. |
Sì |
|
|
00089064 |
EN 15265:2007 |
Energy performance of buildings - Calculation of energy needs for space heating and cooling using dynamic methods - General criteria and validation procedures |
This standard specifies the assumptions, boundary conditions and validation tests for a calculation procedure for the annual energy demand for heating and cooling of a building (or of a part of it) able to produce hourly profiles of the demand. |
Sì |
|
|
00089111 |
EN ISO 13790:2008 |
Energy performance of buildings - Calculation of energy use for space heating and cooling (ISO 13790:2008) |
This International Standard is one of a series of calculation methods for the design and evaluation of thermal and energy performance of buildings. It presents a coherent set of calculation methods at different levels of detail, for the energy use for the space heating and cooling of a building, and the influence of the recoverable thermal losses of technical buildings systems such as the heating and cooling system. |
Sì |
|
|
00089121 |
EN ISO 12567-1:2010 |
Thermal performance of windows and doors - Determination of thermal transmittance by hot box method - Part 1: Complete windows and doors (ISO/NP 12567-1:2007) |
Text is not available |
Sì 25/11/2010 |
|
|
00089119 |
EN 13363-1:2003+A1:2007 |
Solar protection devices combined with glazing - Calculation of solar and light transmittance - Part 1: Simplified method |
This European Standard specifies a simplified method to estimate the total solar energy transmittance of a solar protection device combined with glazing. |
Sì |
|
|
00089101 |
EN 13947:2006 |
Thermal performance of curtain walls - Calculation of thermal transmittance |
This standard specifies a method for calculation of the thermal transmittance of a curtain walling that consists of glazed and/or opaque panels fitted in frames or sashes, without shutters. |
Sì |
|
|
00089106 |
EN ISO 10456:2007 |
Building materials and produts - Hygrothermal properties - Tabulated design values and procedures for determining declared and design thermal values (ISO 10456:2007) |
This International Standard specifies methods for the determination of declared and design thermal values for thermally homogeneous building materials and products, together with procedures to convert values obtained under one set of conditions to those valid for another set of conditions. These procedures are valid for design |
Sì |
|
Codice progetto |
Codice Norma |
Titolo |
Sommario |
Pubblicazione UNI |
|
---|---|---|---|---|---|
00089068 |
EN ISO 15927-5:2004 |
Hygrothermal performance of buildings - Calculation and presentation of climatic data - Part 5: Winter external design air temperatures and related wind data (ISO/DIS 15927-5:2002) |
This standard specifies the definition, method of calculation and method of presentation of winter external design temperatures, used in determining the maximum heat requirements for space heating in buildings. This is linked to a measure of wind speed, for locations where low temperatures occur in conjunction with windy conditions. |
Non prevista |
|
00089062 |
EN ISO 13791:2004 |
Thermal performance of buildings - Calculation of internal temperatures of a room in summer without mechanical cooling -- General criteria and validation procedures |
This Standard specifies the assumptions, boundary conditions and validation tests for a calculation procedure, under transient hourly conditions, of the internal temperatures, air and operative, during the warm period, of a single room without any cooling/heating equipment. Validation tests are included. No specific numerical techniques are imposed by this standard. An example of a solution technique is given. |
Non prevista |
|
00089063 |
EN ISO 13790:2004 |
Thermal performance of buildings - Calculation of energy use for space heating |
This standard gives a simplified calculation method for assessment of the heat use and energy needed for space heating of a residential and non residential building, or a part of it, which will be refered to as "the building". No form of mechanical cooling is considered. This method includes the calculation of: 1) the heat losses of the building when heated to constant temperature; 2) the annual heat required to maintain the specified set-point temperatures in the building; 3) the annual energy required by the heating system of the building for space heating. |
Non prevista |
|
00089019 |
EN 13363-1:2003 |
Solar protection devices combined with glazing - Calculation of solar and light transmittance - Part 1 : Simplified method |
This European Standard specifies a simplified method based on the thermal transmittance and total solar energy transmittance of the glazing and on the light transmittance and reflectance of the solar protection device to estimate the total solar energy transmittance of a solar protection device combined with glazing. The method applies to all types of solar protection devices parallel to the glazing such as louvre, venetian or roller blinds. The position of the solar protection device can be interior, exterior or between single panes in a dual glazing system. It is applicable when the total solar energy transmittance of the glazing is between 0,15 and 0,85. Venetian or louvre blinds are assumed to be adjusted so that there is no direct solar penetration. It is assumed that for external solar protection devices and for integrated solar protection devices, the space between the solar protection devices and the glazing is unventilated and for internal solar protection devices this space is ventilated.The resulting g-values of the simplified method given here are approximate and their deviation from the exact values lie within the range between +0,10 and -0,02. The results generally tend to lie on the safe side for cooling load estimations. The results are not intended to be used for calculating beneficial solar gains or thermal comfort criteria.The simplified method is based on the normal incidence of radiation and does not take into account either the angular dependence of transmittance and the reflectance or the differences of spectral distribution. An allowance can be made for this fact when applying the method. |
Non prevista |
|
00089102 |
EN ISO 13786:2007 |
Thermal performance of building components - Dynamic thermal characteristics - Calculation methods |
This International Standard specifies the characteristics related to the dynamic thermal behaviour of a complete building component and provides methods for their calculation. It also specifies the information on building materials required for the use of the building component. |
Non prevista |
|
00089044 |
EN ISO 13792:2005 |
Thermal performances of buildings - Internal temperatures of a room in summer without mechanical cooling - General criteria for a simplified calculation method (ISO/DIS 13792:1997) |
This standard sets out the level of input and output data, and prescribes the boundary conditions required for a calculation method to determine the maximum, average and minimum daily values of the dry resultant temperature of a room in the warm period for the following purposes: a) to define the characteristics of a room in order to avoid overheating in summer at the design stage; b) to define whether the installation of a cooling system is necessary or not. Annex A includes the criteria to be met by a calculation method in order to satisfy this standard. |
Non prevista |
|
00089112 |
UNI CEN/TS 15548-1:2011 |
Thermal insulation products for building equipment and industrial installations - Determination of thermal resistance by means of the guarded hot plate method - Part 1: Measurements at elevated temperatures from 100 °C to 850 °C |
This standard provides the additional information to that given in EN 12667, EN 12664, EN 12939 and |
Non prevista |
|
00089072 |
EN ISO 10077-2:2003 |
Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO/FDIS 10077-2:2003) |
This European Standard specifies a method and gives reference input data for the calculation of the thermal transmittance of frame profiles and of the linear thermal transmittance of their junction with glazings or opaque panels.The method can also be used to evaluate the thermal resistance of shutter profiles and the thermal characteristics of roller shutter boxes.This European Standard also gives criteria for the validation of numerical methods used for the calculation.This European Standard does not include effects of solar radiation, heat transfer caused by air leakage or three-dimensional heat transfer such as pin point metallic connections. Thermal bridge effects between the frame and the building structure are not included. |
Non prevista |
|
00089088 |
EN ISO 6946:1996/A1:2003 |
Building components and building elements - Thermal resistance and thermal transmittance - Calculation method (ISO 6946:1996/Amd. 1:2003) |
Text is not available |
Non prevista |
|
00089096 |
EN ISO 10077-1:2006 |
Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General (ISO 10077-1:2006) |
This part of ISO 10077 specifies methods for the calculation of the thermal transmittance of windows and pedestrian doors consisting of glazed and/or or opaque panels fitted in a frame, with and without shutters. |
Non prevista |
|
00089092 |
EN 15026:2007 |
Hygrothermal performance of building components and building elements - Assessment of moisture transfer by numerical simulation |
This standard specifies the equations to be used in a simulation method for calculating the non steady transfer of heat and moisture through building structures. It also provides a benchmark example intended to be used for validating a simulation method claiming conformity with this standard, together with the allowed tolerances. The equations in this standard take account of the following storage and one-dimensional transport phenomena: - heat storage in dry building materials and absorbed water; - heat transport by moisture-dependent thermal conduction; - latent heat transfer by vapour diffusion; - moisture storage by vapour sorption and capillary forces; - moisture transport by vapour diffusion; - moisture transport by liquid transport (surface diffusion and capillary flow). The equations described in this standard account for the following climatic variables: - internal and external temperature; - internal and external humidity; - solar and longwave radiation; - precipitation (normal and driving rain); - wind speed and direction. The hygrothermal equations described in this standard shall not be applied in cases where: - convection takes place through holes and cracks; - two-dimensional effects play an important part (e.g. rising damp, conditions around thermal bridges, effect of gravitational forces); - hydraulic, osmotic, electrophoretic forces are present; - daily mean temperatures in the component exceed 50 °C. |
Non prevista |
|
00089103 |
EN ISO 13789:2007 |
Thermal performance of buildings - Transmission Transmission and ventilation heat transfer coefficient - Calculation method |
This International Standard specifies a method and provides conventions for the calculation of the steadystate transmission and ventilation heat transfer coefficients of whole buildings and parts of buildings. |
Non prevista |
|
00089107 |
EN ISO 10211:2007 |
Thermal bridges in building construction - Heat flows and surface temperatures - Detailed calculations |
This Standard sets out the specifications for a 3-D and 2-D geometrical model of a thermal bridge for the numerical calculation of: |
Non prevista |
|
00089105 |
EN ISO 13370:2007 |
Thermal performance fo buildings - Heat transfer via the ground - Calculation methods |
This standard gives methods of calculation of heat transfer coefficients and heat flow rates, for building elements in thermal contact with the ground, including slab-on-ground floors, suspended floors and basements. It applies to building elements, or parts of them, below a horizontal plane in the bounding walls of the building situated |
Non prevista |
|
00089089 |
EN ISO 23993:2008 |
Thermal insulation for building equipment and industrial installations - Thermal conductivity - Determination of design values |
This International Standard gives methods to calculate design thermal conductivities from declared thermal conductivities for the calculation of the thermal performance of building equipment and industrial installations. |
Non prevista |
|
00089122 |
UNI EN 16012:2012 |
Thermal insulation for buildings - Reflective insulation products - Determination of the declared thermal performance |
To provide procedures for the use of existing steady-state methods (EN 12667 Thermal performance of building materials - Determination of thermal resistance by means of guarded hot plate and heat flow meter apparatus and EN ISO 8990 Thermal insulation - Determination of steady-state thermal transmission properties - Calibrated and guarded hot box) for the determination of the declared value of reflective insulation products: - For multi-foil insulation - For products with reflective surfaces - For single layer foils or multiple layers in the form of pockets The declared value should represent the value to be expected over a reasonable working life and should include the surface emissivity of the reflective surface. |
Non prevista |
|
00089108 |
EN ISO 6946:2007 |
Building components and building elements - Thermal resistance and thermal transmittance - Calculation method (ISO 6946:2007) |
This International Standard provides the method of calculation of the thermal resistance and thermal transmittance of building components and building elements, excluding doors, windows and other glazed units, curtain walling, components which involve heat transfer to the ground, and components through which air is designed to permeate. |
Non prevista |
|
00089104 |
EN ISO 14683:2007 |
Thermal bridges in building construction - Linear thermal transmittance - Simplified methods and default values (ISO 14683:2007) |
This standard deals with simplified methods for determining heat flows through linear thermal bridges which occur at junctions of building elements. |
Non prevista |
|
00089109 |
EN ISO 12241:2008 |
Thermal insulation for building equipment and industrial installations - Calculation rules (ISO 12241:2008) |
This International Standard gives rules for the calculation of heat transfer related properties of building equipment and industrial installations, predominantly under steady-state conditions. The standard also gives a simplified approach for the treatment of thermal bridges. |
Non prevista |
|
00089123 |
UNI EN ISO 10077-2:2012 |
Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical method for frames (ISO/DIS 10077-2:2009) |
- |
Non prevista |
|